V.V.Iron & Steel, Tuticorin

2013, Tamil Nadu

 

PROJECT DETAILS
12ton, 4mw Induction Furnace and Ingot mold plant at energy efficiency SEC of 800kwh/Ton steel melting
RESULTS ACHIEVED
Harmonic and troubleshooting study for root cause analysis

Shri Mahavir Ferro Alloys Ltd, Rourkela

2008

PROJECT DETAILS
DRI Sponge Iron Plant, 3nos each 4.5mw, 12Ton Induction Furnace, 5.5kva, 11kv/2x1kv, Dd0y11, transformer and Con Cast
RESULTS ACHIEVED
Power Plant 12.5mw, 11kv Grid Synchronized with a 12.5MVA, 33/11kv grid transformer.

Scan Steels Limited, Rourkela

2006

PROJECT DETAILS
SIP Sponge iron plant, 3nos 12ton Induction furnace each with 4.5mw, 4.75kva 11kv/2x1.0kv, Dd0yn11 transformers and Con Cast plant.
RESULTS ACHIEVED
Harmonic Audit with the upstream 8mw,11kv power plant synchronized with Grid through a 10mva, 33/11kv grid transformer.

R.S. Steel, Chittagong, Bangladesh

1998 thro' KEC,

PROJECT DETAILS
Induction furnace and Rolling Mill
RESULTS ACHIEVED
Harmonic Filter (11kV) design consultancy for 2nos 8mva Transformers and 1no DG in Parallel Run with the Grid Supply.

Pushpit Steels Pvt Ltd, Srikalahasti

2015, Tirupati

PROJECT DETAILS
Induction Furnace 2nos 14Ton 12mw, 11kv Power Plant
RESULTS ACHIEVED
Harmonic and troubleshooting study for root cause analysis. of frequent power plant voltage fluctuations, AVR failures and tripping.

Pulkitt Steel Rolling Mills, Pondicherry

2010 -12, Repeat jobs.

PROJECT DETAILS
300TPD TMT 8-36mm bar Rolling Mills. Maximum demand 3000KVA. Energy Efficiency SEC 116kWh/Ton for TMT bar rolling mill.
RESULTS ACHIEVED
Harmonic and troubleshooting study for root cause analysis

OPG Metals, Mailaduthurai

2012, TN

PROJECT DETAILS
3x 15Ton Induction Furnace and Billet Mill. 15mw Power plant. Energy efficiency SEC =730kwh/Ton steel melting shop.
RESULTS ACHIEVED
Harmonic study carried out and report submitted.

MS Agarwal Foundries Pvt. Ltd., Medak

2015, Telangana

PROJECT DETAILS
Induction furnace 25 and 15Ton 300TPD TMT 8-32mm bar rolling mill.
RESULTS ACHIEVED
Root cause analysis of frequent failures of 24pulse, 2x 6000kva, Dy11d0, Dd+15d-15 11kv/0.575kv. 25Ton Induction Furnace Transformer

Mohan Steels, Kanpur

1997, UP

PROJECT DETAILS
Induction furnace and TMT bar rolling mill
RESULTS ACHIEVED
Harmonic study carried out and report submitted.

Hans Metals Ltd. Hamirpur

1997, UP

PROJECT DETAILS
Induction Furnace and TMT bar Rolling Mill plant.
RESULTS ACHIEVED
Root cause analysis for electrical and motor failures